"HUGLE" PEN-TYPE IONIZER MODEL 3080
G/ 3080C
Effective
removal of microscopic dust paricles caused by
static electricity!!!
|
|
Features
Optimum:
A O 1.5mm air outlet and concentrated fast airflow
re most suitable to effectively remove microscopic dust particles. Also, the
body color does not shine because it is black which is excellent for use in
darkroom inspection processes
Imput Power
|
100V -
115V, 50/60Hz, 0.27A
|
Pressure
range
|
0.05-0.6Mpa
(0.5 - 6.0Kgs/cm2)
|
Ambient
Temperature
|
5°C
- 40°C [41°F - 104°F]
|
Ambient
humidity
|
35%RH
- 65% RH [No condensation]
|
Gun
Unit (weight)
|
0.5Kgs
|
Power
supply unit(weight)
|
2.1Kgs
|
|
|
Performance
|
Pen part
and controller part are connected by a low voltage cable (modular cable) for easy
and simplified operation.
|
Safety
|
The
internal safety circuit cuts off HV power when it dectects
an abnormallity in the HV circuit.
|
Clean
|
Uses a
0.01μ Cartridge type filter.
|
|
Maintenance
Very eash to clean the emitter needle and also replace it
Option
Polysilicon Emitter needle [Standard: Tungsten Emitter needle]
Footswitch
|
Model
3080G Pen Part Unit
|
Output
Voltage
|
2000Vrms
[volts root mean square]
|
Output
Frequency
|
70 - 80kHz
|
Output
Display
|
During
HV output LED (red) is ON
|
Amount
of Air-Flow
|
10 -
34 L/min (gas presure 0.05 - 0.3Mpa)
|
Ambient
Temperature
|
10°C
- 40°C
|
Ambient
Humidity
|
35% RH
- 65%RH [Non-Condensing]
|
weight
|
130g
|
|
Model 3080C
Controller Unit
|
Input
Voltage
|
DC24V
[Using
an AC Adaptor: AC90V-AC264V 50/60Hz, Power Cord: For AC100V - AC120V]
|
Input
Current
|
[0.5A
Max]
|
Output
Voltage
|
2000Vrms
|
Output
Frequency
|
70 -
80 kHz
|
Output
Display
|
During
HV Output HV LED (green) is On
During Abnormality of HV ALARM LED (red) is On
Buzzer Operaion [can be truned
On/Off]
|
Purge
Gas
|
0.3MPa
Max
[Pressure Speed Control is adjustable]
|
Ambient
Temperature
|
0°C
- 40°C
|
Ambient
Humidity
|
35% RH
- 65%RH [Non-Condensing]
|
Weight
|
750g
|
|
|