New Generation
|
|
2-wire Melt Pressure Transmitter
|
|
with excellent Noise Suppression and
|
|
“Auto-Zero” Push-Button-Function
|
|
Series MDT4X2F
|
|
Description
|
|
The new
Pressure Transmitter Series MDT provides special features for critical field
applications in
|
|
high noise surroundings.
|
|
The utilization
of unshielded cables is also possible for long distance transmission free of
noise
|
|
interference for the converted process pressure signal 4-20 mA.
|
|
Features
|
|
Simple and cheap
unshielded two-wire cable connection in high noise ambients
|
|
Efficient
“Auto-Zero” adjustment either through pushbutton on the
transmitter or in the control room
|
4-20 mA two-wire Signal Output
|
|
Electrical built-in
calibration
|
|
Installation for media
temperatures up to 400๐C
|
|
Flexible capillary connection
between stem with diaphragm and housing
|
|
Failure detection
through “fail-safe” signal levels acc. to NAMUR recommandation
NE43
|
|
Technical Data
|
|
Pressure
range
|
0-17 bar
to 0-2000 bar
|
|
Accuracy
|
MDT422F +/-0.5%FSO
– up to 50 bar +/-1%FSO
MDT462F +/-1%FSO
|
|
Repeatablility
|
MDT422F
+/-0.1%FSO
–
up to 50 bar +/-0.2%FSO
MDT462F +/-0.2%FSO
|
|
Resolution
|
infinite
|
|
Maximum
overload (without influencing operation data)
|
2 x
pressure range for range 1000 and 1400
bar max. 1750 bar and max. 2400 bar for range 2000 bar
|
|
Burst pressure
|
6 x pressure range max. 3000 bar
|
|
Material
in contact with Media
|
15-5 PH
SST (Mat. No. 1.4545) DyMAXTM coated
|
|
Electrical Characteristics
|
|
Configuration
|
4-arm. Wheatstone
bridge strain gauge (DMS)
|
|
Internal Shunt-Calibration
|
80% of full scale +/-1%
|
|
Output
signal
|
2-wire
4-20 mA
|
|
Supply voltage
|
12-36 V DC
|
|
Zero
balance
|
Through
“Auto-Zero” adjustment function
|
|
“Auto-Zero” initiation
|
In the field on the transmitter,
“Zero-push-button”, or externally via
“short circuit” between contacts “NP”
and “GND”
|
|
Range
Calibration 80% FSO
|
“Short
circuit” between connection pins “CAL” and
“GND” at the transmitter or externally from the control room
|
|
Load resistance
|
Maximum 1200Ω at 36 V DC
Maximum 500Ω at 24 V DC
|
|
Isolation
resistance
|
1000 MΩ
at 50 V DC
|
|
“Fail-Safe” signal levels
|
Signal levels acc. to NAMUR
recommendation
NE43: <=3,6 mA or >= 21,5 mA
|
|
Temperature Influence
|
|
Diaphragm
|
|
Max.
Temperature
|
400๐C
|
|
Zero
shift due to temperature change
|
MDT422F
< 0.2 bar/10๐C
MDT462F < 0.4 bar/10๐C
|
|
Housing
|
|
Max.
Temperature
|
85๐C
|
|
Zero shift due to temperature change
|
+/-0.2% FSO/10๐C
|
|
Sensitivity
shift due to temperature change
|
MDT422F
+/-0.1% FSO/10๐C
-up to
50 bar +/-0.2% FSO/10๐C
MDT462F +/-0.3% FSO/10๐C
|
|