Small
and robust, ergonomic and intuitive, economic and powerful – the Dräger Pac 7000
|
is tailor-made for personal monitoring at the
workplace. This innovative single gas detector
|
is
equipped with a wide range of functions and is suitable for many different
applications in
|
day-to-day industrial settings. The detector is an impressive
instrument, offering a high level
|
of
reliability and rapid warning against harmful concentrations of CO, CO2, Cl2, HCN, H2S,
|
NH3, NO2, O2, PH3,
SO2.
|
Dräger Pac 7000 at a glance
|
-˙˙˙
Gas inflow from top and front
|
-˙˙˙
Adjustable operating time with pre-and
|
-˙˙˙
Unlimited instrument life
|
˙˙ main alarm
|
-˙˙˙
Easy sensor replacement
|
-˙˙˙
Adjustable bump test interval
|
-˙˙˙
No-text display (no language ˙˙˙problems)
|
-˙˙˙
Adjustable bump test mode
|
-˙˙˙
Continuous concentration display
|
-˙˙˙
Password-protected menu for fresh air
|
-˙˙˙
Visual alarm
|
˙ and sensitivity calibration
|
-˙˙˙
Audible alarm
|
-˙˙˙
IR interface
|
-˙˙˙
Vibration alarm
|
-˙˙˙
Individual instrument configuration
|
-˙˙˙
Two adjustable alarm thresholds
|
-˙˙˙
Replaceable battery
|
-˙˙˙
Adjustable TWA alarm
|
-˙˙˙
Data logger
|
-˙˙˙
Adjustable STEL alarm
|
˙
|
-˙˙˙
Display of peak concentration
|
˙
|
-˙˙˙
Battery pre- and main alarm
|
˙
|
TECHNICAL DATA
|
Dimensions
(H
x W x D)
|
64
x 84 x 20 (battery compartment: 25) mm (2.5 x 3.3 x0.8 in.,
battery compartment:1 in.)
|
Weight
|
120 g (3.8 oz.)
|
Ambient
conditions
|
Temperature 1) ˙˙˙˙˙˙
|
-30
to 50๐C (-20 to 120๐F)
|
Pressure
|
700
to 1300 hPa
|
Humidity
|
10
to 90% r.h.
|
Ingress protection
|
IP 65
|
Display
|
Language-free
LCD display, continuous indication of concentration, indication of
concentration during alarm, peak concentration, TWA-and STEL-concentration, operating
time, notice and warning functions
|
Typical battery life
|
3 years (O2 sensor 1.5 years)
|
Acoustic
alarm
|
Two-tone-alarm,
typical > 90 dB(A) at a distance of 30 cm
|
Data logger
|
Storage of concentration and events with date and time
|
Approvals
|
CE-Sign
(89/336/EEC, 94/9/EC)
|
ATEX
|
II
1 G EEx ia IIC, T4
I
M 1 EEx ia I, T 4
|
UL
|
Class
I, II, Div 1, Group A, B, C, D, E, F, G, Temp. Code T4
|
cUL
|
Class
I, II, Div 1, Group A, B, C, D, E, F, G, Temp. Code T4
|
IECEx
|
EEx ia IIC, T4
|
1) Dräger Pac 7000
CO2 : -20 to 40๐C (-4 to 104๐F)
|
ORDER INFORMATION
|
Description
|
Measuring
|
Alarms
Threshold A 1
|
Alarms
Threshold A 2
|
Order-code
|
Dräger Pac 7000 O21)
|
0 to 25 Vol.-%
|
19 Vol.-%
|
23 Vol.- %
|
83 18 675
|
Dräger Pac 7000 O22)
|
0 to 25 Vol.-%
|
19.5 Vol.-%
|
23.5 Vol.- %
|
83 18 972
|
Dräger Pac 7000 O2
|
0 to 25 Vol.-%
|
By coustomer request
|
83 18 678
|
1) Default configuration Europe
|
2) Default configuration NAFTA
|
|
|
|
|
|
|
|