CDI Computorq II ™
|
Computorq II ™ Digital
Electronic Torque Wrench
|
·
Largest Storage Capacity Available
|
Up to 4000 torque
values can be stored in memory. An audible tone signals when memory is full.
|
·
Down Loading Capacity
|
Computorq II is equipped to
down-load individual torque values or store values in memory which
|
can be directly
down-loaded to a printer/computer or datalogger via
RS232.
|
·
Selectable Modes of Operation
|
"Peak Hold"
and "Track" modes of operation are standard. Computorq
II's electronics are far
|
superior to our
competitors in capturing real torque value in "Peak" mode
|
·
Easy Set-Up
|
Target torque values
(high and low percentage, +/- tolerances and torque engineering units) are
|
easily programmed through
the keypad and shown on the LCD.
|
·
Quality Construction
|
Proven industrial
quality. Designed for continuous use.
|
·
Range
|
Available from 5
in. lb. to 1000 ft. lb.
|
·
Batteries
|
A 9V alkaline battery
is standard and provides enough power for 60 hours of operation.
|
A "LO BAT" indication on the display signals for
replacement.
|
·
Accuracy
|
+/- 1% From 20-100% of
scale
|
+/- 1%, plus 5
increments, from 10 -20% of scale
|
·
Calibration Data
|
All calibration
data is stored in the microprocessor
|
·
Baud Rate
|
The baud rate for
downloading to a printer/computer/data logger is selectable. The factory set
|
rate is 1200. Options are 300, 600, 1200
2400, 4800, 9600 or 19,200.
|
|
PART NUMBER
|
DRIVE
|
RANGE
|
INCREMENTS
|
LENGTH IN
|
WEIGHT LBS.
|
6004 CF-II
|
3/4”
|
60-600 ft.lb.
|
.1 ft.lb.
|
46.5”
|
9.5”
|
81-813 Nm
|
.1 Nm
|
8.3-83 mKg
|
.01 mKg
|
|
|
|
|
|
|