CHROMAIR
|
SYSTEM
|
|
§ Immediate,
on-site results
|
§ Easy-to-read
color change
|
§ Highly
sensitive and selective
|
§ Exposure
data read directly from badge
|
§ Measure
TWA exposure
|
§ Immediate
response for short-term exposure measurements
|
§ Patented
design minimizes effects of humidity and velocity
|
§ Light-weight
and cost effective for personnel and area monitoring
|
|
Principle of Operations
|
The
ChromAir badge is a colorimetric direct-read
monitor. It relies on the principle of diffusion;
|
therefore it
requires no pump to operate. Unlike traditional diffusion tubes, the patented
design
|
of
the ChromAir badge provides a short and constant
diffusion path irrespective of the sampling
|
time or
concentration. This unique feature provides accurate results immediately and
throughout
|
the sampling
period.
|
|
The
ChromAir monitor provides the user with six
exposure levels. Most ChromAir badges indicate
|
from 1/10 to 2
times the time-weighted-average (TWA) for an eight hour work period. The scale
|
printed
on the badge and color comparator is based on exposure dose [parts per
million times
|
hour (ppmhr)]. To determine the average concentration, locate
the highest cell with a color
|
change and
divide the corresponding dose level (ppmhr) by the
sampling time in hours (hr).
|
EXAMPLE:
If the sampling time is 2 hours and the badge reads 40 ppmhr,
the average concentration
|
is determined
by: 40 ppmhr/2hr. Therefore, the time weighted
average concentration is 20 ppm.
|
|
PART#
|
ANALYTE
|
RANGE
(ppmhr)
|
INTERFERENCES
|
380003
|
Ammonia
|
4
- 300
|
RNH2
|
380008
|
Carbon
Monoxide
|
10
- 525
|
Alkenes,
H2, H2S
|
380004
|
Chlorine
|
0.4
- 13
|
Br2,
I2, HCl
|
380007
|
Formaldehyde
|
0.3
- 12
|
Acrolein
|
380017
|
Glutaraldehyde
|
0.04
0.95¹
|
None
Known
|
380018
|
Mercury
|
0.125
1.6 ²
|
Strong
Oxidizers
|
380010
|
Ozone
|
0.08
1.6
|
H2O2,
NO2 ³
|
|
¹ ChromAir glutaraldehyde
STEL badges are for 15 minutes of monitoring only. The scale on the
|
Badge is in ppm.
|
² ChromAir mercury
badge and color comparator scale is in mg/m³hr
|
³ ChromAir ozone
badges are ten times more sensitive to ozone than nitrogen dioxide.
|