Radalert 100X™ Nuclear
Radiation Monitor
|
|
The
Radalert 100X™ measures alpha, beta, gamma, and
X-radiation. Its digital display shows
|
readings in your
choice of counts per minute (CPM) µSv/hr or mR/hr
or in accumulated counts.
|
A
red LED blinks and a beeper chirps with each count (the chirp can be muted).
An audible
|
alert sounds
when the radiation reaches a user-adjustable level.
|
|
§ Monitor
personal radiation exposure
|
§ Monitor an
area or perimeter
|
§ Detect
radiation leaks and contamination
|
§ Ensure
regulatory compliance
|
§ Monitor
changes in background radiation
|
§ Demonstrate
principles of nuclear physics
|
§ Check for
radioactive minerals in the earth
|
|
Technical Specifications
|
Detector:
|
Halogen-quenched
Geiger-Mueller tube (LND 712)
Mica
end window density 1.5-2.0 mg/cm²
Side
wall is 0.012” #446 stainless steel
Detects
Alpha, Beta, Gamma, and X-radiation
|
Display:
|
4-digit
liquid crystal display with mode indicators
|
Operating
Range:
|
µSv/hr: .000-1,100
mR/hr: .000-110
CPM: 0 to 350,000
CPS: 0
to 3,500
Total: 0 to
9,999,000 counts
|
Calibration:
|
Cesium
-137 (gamma)
|
Gamma
Sensitivity:
|
1,200
CPM/mR/hr referenced to
Cs-137
|
Accuracy:
|
+/-10%
typical; +/-15% maximum
|
Alert
Range:
|
User-adjustable
alert level to 500 µSv/hr
& 60,000 CPM
|
Count
Light:
|
Red
LED flashes with each count
|
Audio:
|
Beeper
chirps for each count (can be muted)
|
Ports:
|
-
Output: Stereo 3.5 mm jack sends counts to computers, data loggers,
other CMOS-compatible devices,
earphones, and educational data
collection
systems.
0.9 V, 1 kOhm
impedance.
-
Input: 2.5 mm mono jack provides calibration input.
0-3.3 V, >5 µs width, rising edge
triggered.
|
Anti-Saturation:
|
Readout
holds at full scale in fields up to 100 times the maximum reading
|
Temperature
Range:
|
-20° to +50ºC, -4º to +122ºF
|
Timer:
|
Can
set sampling periods of 1 minute to 40 hours
|
Averaging
Periods:
|
Display
updates every 3 seconds, showing the average for the past
90-second
time period at normal levels. The Averaging period decreases
as the
radiation level increases.
|
Power:
|
One
9-volt alkaline battery; battery life 2,000 hours typical, 700 hours
minimum at normal
background radiation levels at sea level. Battery life
decreases as
radiation level rises.
|
Size:
|
150
x 80 x 30 mm (5.9” x 3.2” x 1.2”)
|
Weight:
|
225
grams (8 oz) including battery
|
Options:
|
Computer
software and cable available
|
Certifications:
|
CE
Certified:
Emissions:
EN 55011:2009 + A1:2010 (Class B emissions limits);
EN
61326-1: 2006 (Class B) RF Emissions
Immunity:
EN 61326-1:2006 (Annex C) Portable Test and Measurement
Equipment;
EN 61000-4-2: 1995 (ESD); EN 61000-4-3: 1997 (EM)
RoHS
Compliant; Meets WEEE standards
|