Coating Thickness
Measurement
|
MiniTest
725 • 735 • 745
|
|
The
intelligent solution for coating thickness measurement
|
§ Modular
design made-to-measure
|
§ With
built-in, external or convertible sensors
|
§ Bluetooth
for data transfer to a PC, Tablet-PC or smartphone
|
§ Wireless
sensors
|
§ Special
miniature and tube sensors
|
|
Practice-oriented and versatile
|
MiniTest 725 with a
built-in sensor is especially suited for quick measurement on car bodies,
|
hulls or steel
constructions. Thanks to its ergonomic design for one-handed operation all
|
functions can be
easily accessed with one hand only.
|
|
MiniTest 735 with an
external sensor combines high precision and ease of measurement.
|
The
cable-connected sensor ensures convenient measurement on objects difficult to
access.
|
|
MiniTest 745 – the top
model of the series – convinces through its flexible sensor design. Its
|
built-in sensor
can be easily converted into an external sensor. Thus you can take advantage
|
of the
features of both sensor designs. Additional comfort and flexibility is
provided by the
|
wireless sensor.
|
|
Special sensors adapted to difficult conditions
|
In
addition to the comprehensive range of standard sensors, ElektroPhysik
offers a number of
|
special
sensors for particularly difficult applications:
|
§ FN 2.6
sensor, particularly adapted for measurement on car bodies, highly
unsusceptible to varying geometries or base materials.
|
§ Miniature
sensors in 0°, 45° or 90° design for measurement on thin layers and very
small surfaces, in grooves, bore holes or recesses
|
§ HD-sensors
for heavy-duty use in rough environments, with the sensor electronics
especially protected against dust, paint or other aggressive substances
|
§ Tube
sensors with grip extension for easy access in pipes and tubes
|
|
Technical Data
|
Dual
sensors
|
Automatic
recognition of the substrate material with FN sensors
|
Data
memory
|
10
batches for a maximum of 10,000 readings (MiniTest
725 and 735)
100
batches for a maximum of 100,000 readings (MiniTest
745)
Memories
can be partitioned as needed.
|
Statistical
evaluation
|
Number
of readings, min, max, mean value, standard deviation, coefficient of
variation, single value statistics, blocks statistics
(norm-conforming/
freely configurable)
|
Calibration
modes
|
Factory
calibration, zero-point-, 2-point-, 3-point-calibration,
calibration
method “rough”
|
Calibration
procedures according to
International
standards
|
ISO,
SSPC, “Swedish”, “Australian”
|
Monitoring
of limits
|
Visual
and audible signal output
|
Measuring
units
|
Switchable
from metric (µm, mm, cm) to imperial (mils, inch, thou)
|
Measuring
rate
|
70
readings per minute in the single mode
20
readings per second in the continuous mode
|
Continuous
mode
|
For
quick identification of thickness variations
|
Operating
temperature
|
-10°C
… 60°C
|
Storage
temperature
|
-20°C
… 70°C
|
Data
interfaces
|
USB
and Bluetooth
|
Power
supply
|
2
pcs batteries, type AA (Mignon); rechargeable NiMH batteries,
type AA/HR6 as
an option. Battery or rechargeable battery setting option to adapt to the
matching nominal voltage
|
Norms
and standards
|
DIN
EN ISO 1461, 2064, 2178, 2360, 2808, 3882, 19840,
ASTM
B 244, B 499, D7091, E 376, AS 3894.3, SS 1841 60, SSPC-PA2
|
|
|
|