PORTAFLOW D550
|
|
Non-Contacting
|
|
Doppler Flow Meter
|
|
|
|
Use a PF D550 Portable Doppler Flow Meter to
monitor and balance flow, or to troubleshoot
|
|
flow problems
in full pipes. It is ideal to evaluate performance of in-line flow meters and
can
|
|
be installed,
calibrated and started-up in minutes. Use it for projects where a permanent
|
|
flowmeter
is not required or to temporarily replace installed flow transmitters.
|
|
|
|
The PF D550 ultrasonic sensor is
clamped on the outside of a pipe. An acoustic pulse is reflected
|
|
back to the sensor from particles or gases in the flowing
liquid. The flow rate of any fluid can be
|
|
measured as long as it contains air bubblers or solids. It is
ideal for wastewater, slurries, sludge and
|
|
most chemicals, acids, caustics and lubrication fluids. With
its internal battery the PF D550 can be
|
|
operated all day and then recharged overnight. For continuous
use it can be powered by a
|
|
supplied 110-240VAC wall plug adapter. A 300,000 point data
logger is built-in.
|
|
|
|
General Specifications
|
PORTAFLOW D550 Portable Doppler Flow Meter
|
|
Flow Rate Range:
|
+/-0.03 to 12.2 m/sec (+/- 0.1 to 40 ft/sec) in most applications
|
|
Pipe Size:
|
Ultrasonic sensor mounts on any
pipe from 12.5 mm to 4.5 m (1/2 to 180 ID)
|
|
Display:
|
White, backlit matrix displays flow rate,
totalizer, operating mode and calibration menu
|
Power Input:
|
Built-in NiMH battery for up to 18
hours continuous operation
External charger with 100-240 VAC
50/60 Hz input
|
|
Outputs:
|
4-20 mA (500 ohm) when AC powered
USB for Data Log transfer by direct PC
connection
|
|
Data Logger:
|
Programmable 300,000 data point
capacity, time and date stamped or formatted reports including total,
average, minimum, maximum and
times of occurrence
|
|
PC Software
|
Logger for Windows retrieves, displays and
saves data log files
|
|
Electronics Operating Temperature:
|
-23° to 60°C
(-10° to 140°F)
|
|
Electronics Enclosure:
|
Portable, ABS enclosure
|
|
Carry Case:
|
Rated IP67 with protective molded
foam insert
|
|
Accuracy:
|
2% of full scale,
requires solids or bubbles minimum size of 100 microns, minimum concentration
75 ppm. Repeatability: +/-0.25%, Linearity: +/-0.5%
|
|
Calibration:
|
Built-in 5-key programming with
user-friendly calibration menu, password protected
|
|
Language Selection:
|
English, French, Spanish
|
|
Sensitivity:
|
Adjustable cut-off, Damping:
adjustable
|
|
Approvals:
|
Charger is CE and UL approved. The PF D550 is
not certified for use in hazardous rated locations
|
|
|
|
Sensor Specifications
|
|
|
Standard Model PSE4:
|
Clamp-on, single-head ultrasonic for pipes from
12.5 mm to 4.5 m (1/2 to 180 ID)
with 3.4 m (12 ft)
shielded dual-coaxial cable
|
|
Sensor Mounting Kit:
|
Stainless steel pipe clamp and 150
g (5.3 oz.) silicone coupling compound
|
|
Operating Temperature:
|
-40° to 120°C (-40° to 250°F)
|
|
|
|
Options
|
|
|
Sensor Cable:
|
15 m (50 ft) sensor
cable extension, shielded, with connectors
|
|
Sensor Mounting:
|
Extra silicone coupling compound.
Additional stainless steel pipe clamps
|
|
|
|
Recommended for:
|
|
§ Sewage
|
§ Treated Wastewater
|
|
§ Aerated Water
|
§ Sludge and Slurries
|
|
§ Chemicals and Solvents
|
§ Viscous Liquids
|
|
§ Abrasives
|
§ Food Products
|
|
§ Pulp Stock
|
§ Acids and Caustics
|
|
|
|
The PF D550 is ideal to measure full pipe flow
of any liquid containing gas bubbles or solids larger than 100 microns
|
|
and in
concentrations greater than 75 ppm.
|
|
|
|
|
|
|
|
|