1490 5 Digit 1/8 DIN
|
|
Panel Indicator
|
|
|
|
Features
|
|
·
Universal Input
|
·
Min/Max Value Hold
|
|
·
2 Alarm Outputs
|
·
Modbus Communications
|
|
·
Retransmission
|
·
Transmitter Power supply
|
|
|
|
Description
|
|
The
1490 is a Universal Input Indicator with single or dual configurable alarms,
optional linear
|
|
retransmission
of Process Variable, Transmitter power supply option as well as optional
Modbus
|
|
communications.
|
|
|
|
Technical
Data
|
|
FEATURES
|
|
Output
Configuration
|
1
or 2 relay outputs, with optional linear retransmission
|
Alarms
|
2
process high/low with adjustable hysteresis
|
Viewable
Values
|
Process
variable, maximum value, minimum value
|
Human
Interface
|
3
button operation, 5 digit 13mm high display red, green, 2 alarm indicator
|
INPUT
|
Thermocouple
|
J,
K, C, R, S, T, B, L, N & PtRh20%vsPtRh40%
|
RTD
|
3
Wire PT100, 50Ω per lead maximum (balanced)
|
Strain
Gauge
|
350
Ohm Strain Gage
|
Bridge Connection:
|
4
or 6 wire (6 to use internal shunt cal switch)
|
Bridge Excitation:
|
10V
+/-7%
|
Bridge Sensitivity:
|
1.4
4 mV/V
|
Input Signal Span:
|
-25%
to +125% of full scale (approximately -10mV to +50mV)
|
Calibration:
|
Internal
switch between CAL2 & CAL1 terminals. External resistor only.
|
Shunt Value:
|
From
40% to 100%
|
DC
Linear
|
0
to 20mA, 4 to 20mA, 0 to 50mV, 10 to 50mV,
0
to 5V, 1 to 5V, 0 to 10V, 2 to 10V.
|
Scaleable:
|
1999
to 99999, with adjustable decimal point
|
Impedance
|
>10MΩ
for Thermocouple and mV ranges, 47KΩ for V ranges and 5Ω for mA
ranges
|
Accuracy
|
+/-0.1%
of input range +/-1LSD (T/C CJC better than 1๐C)
|
Sampling
|
10
per second, 16 bit resolution approximately (100ms sample time)
|
Sensor
Break Detection
|
<2
seconds (except zero based DC ranges),
high
alarms activate for T/C, RTD and mV ranges,
low
alarms activate for mA or V ranges
|
OUTPUTS & OPTIONS
|
Alarm
Relays
|
Contact
Single Relay SPDT 2 Amp resistive at 240V AC, >500,000 operations.
Latching
or non-latching. Dual Relay SPST 2 Amp resistive at 240V >200,000
operations. Reinforced safety isolation from inputs and other outputs.
|
DC
Linear Retransmit
|
|
Outputs
|
0
to 20mA, 4 to 20mA into 500Ω max, 0 to 10V,
2
to 10V, 0 to 5V into 500Ω min.
15
¾ bit (1 part in 52K) and updated at about 65ms intervals. (130ms settling
time)
Stability:
+/-76ppm
|
Transmitter
Power
|
|
Supply
|
Output
24VDC (nominal) into 910Ω minimum to power external devices
|
Serial
Communications
|
2
Wire RS485, 1200 to 19200 Baud, Modbus
|
Logic
Input
|
External
reset of latched relay, stored alarm 1 elapsed time, stored min/max PV values
or initiate tare function. Action occurs on high (3 to 5VDC) to low
<0.8VDC, or Open to Closed transition.
|
OPERATING & ENVIRONMENTAL
|
Temperature
& RH
|
0
to 55๐C (-20 to
80๐C
storage), 20% to 95% RH non-condensing
|
Power
Supply
|
85
to 264V 50/60Hz 7.5VA (optional 20 to 48V AC 7.5VA/22 to 65V DC 5 watts)
|
Front
Panel Protection
|
IEC
IP66 (Behind panel protection is IP20)
|
Standards
|
CE.
Pollution Degree 2, Installation Category II UL Listed.
|
|
|
|
|