MIT515, MIT525, MIT1025, MIT1525
|
5
kV, 10 kV, 15 kV DC Insulation Resistance Testers
|
|
30
TΩ maximum resistance
|
Unique
dual-case design provides additional user protection
|
Operate
from battery or AC source
|
Rapid
charge Li-ion battery
|
Safety
rated CATIV 1000 V to 3000 m (15 kV)
|
Advanced
memory with time/date stamp
|
|
MIT515
|
5
kV go/ no-go insulation resistance tester, insulation tester
|
Measures up to 10 TΩ
|
Selectable test voltage from 250 to 5000 V
|
PI, DAR, DD test
|
Improved productivity – operate from line power/mains if battery dead
|
Li ion battery - extended capacity, rapid charge
|
CATIV 600 V safety rating
|
|
Offering CAT IV, the MIT515 is the simplest of Megger's new range of small light 5 kV insulation
|
resistance testers for the testing and maintenance of high voltage electrical
equipment.
|
Enclosed in a tough case it is both smaller and
lighter than its predecessor making it
|
even easier
to carry and store.
|
|
Now equipped with lithium ion fast rechargeable
batteries, the instrument has a large, clear,
|
easy to read, display making it equally suitable
for use in both bright sunlight and poorly lit
|
environments. Information displayed includes resistance, voltage, leakage current,
capacitance,
|
battery status and time constant. In addition, the elapsed time of the test
is displayed constantly
|
removing
the need for separate timer.
|
FEATURES AND BENEFITS
|
Insulation
resistance up to 30 TΩ @ 15 kV, 20 TΩ @ 10 kV, 10 TΩ @ 5 kV enables
installation testing and long-term trending of higher value
apparatus, typically above 1 TΩ.
|
High
altitude operation up to 3000 m while maintaining CATIV 600 V (5 kV and 10
kV) and CATIV
1000V (15 kV).
|
5%
accuracy all the way up to 1 TΩ @ 5 kV, 2 TΩ @ 10 kV, and 3 TΩ @ 15 kV
ensures highest accuracy where it matters most.
|
IR, timed
IR, DAR, PI, DD, SV and ramp tests maximize diagnostic testing capability.
|
3
mA short circuit current with unique max power
regulations technology ensures maximum transfer whatever the load until
selected voltage is reached.
|
Noise
filter rejects up to 3 mA (5 kV and 10 kV) and 6 mA (15 kV) noise for effective operation in electrically
noisy environments.
|
Li-ion
battery allows up to 6 hrs continuous testing @ 5 kV with a 100 MΩ load;
battery meets IEC 62133.
|
Large
backlit LCD, convenient for use in ambient lighting, clearly shows analog and
digital readings.
|
Dedicated
voltmeter function (30 V to 660 V) allows the user to check for induced
voltages.
|
Smaller
size and lighter weight allows easier transport and use without compromising
performance.
|
Unique
dual case design allows for fire-retardant protection while maintaining
ruggedness.
|
High-quality,
flexible silicon test leads meet safety regulations of IEC 61010-31:2008
while ensuring measurement accuracy.
|
Timed
IR plus PI, DAR, DD, SV and ramp tests maximize diagnostic testing
capability.
|
Operate
from line power even if the battery is fully discharged (charges while
operating).
|
Two
and one-half hour full battery charge time (one-half hour charge for one hour
testing) significantly increases productivity.
|
Up to six
hours continuous testing (5 kV) on a single battery charge.
|
Industry
best guard terminal performance to insure highest accuracy of measured
values.
|
Enhanced
driver technology provides plug-and-play when connected to the internet. No
tedious and potentially interruptive setup procedures.
|
Rotary
switch operation for easy, intuitive field use.
|
Locking
test leads provide additional safety.
|
Date
and time-stamped test results reduce the risk of error in result
interpretation.
|
|
APPLICATIONS
|
The
Insulation Resistance (IR) test is a quantitative test which indicates the
effectiveness of a product’s
|
electrical insulation.
Applications include cables, transformers, motors/ generators, circuit
breakers and
|
bushings.
|
|
The
units are designed for testing the insulation of high-voltage electric
equipment. Their wide voltage range
|
also allows
applications for low-voltage equipment. The test techniques on the
instruments provide valuable
|
diagnostic information.
|
|
All four instruments test the insulation resistance of:
|
High-voltage
power cables and high-voltage buses
|
Large
motor/ generator windings
|
Line
and substation transformers
|
|
The
MIT525, MIT1025 and MIT1525 also perform spot tests, step voltage tests,
dielectric discharge tests, ramp
|
tests,
and dielectric absorption tests for the following applications:
|
Acceptance
testing at installation to check conformance to specifications.
|
Routing
preventive/ predictive maintenance testing after installation.
|
QA testing
as part of the manufacturing process.
|
Diagnostic
testing to isolate faulty components for repair.
|