Dual
Independent Footwear and Wrist Strap Tester
|
The EMIT Dual Independent Footwear and Wrist Strap Tester is
designed to test personnel
|
grounding devices, wrist strap and ESD footwear, to satisfy the
requirements of the ESD
|
Association.
|
|
Per
ANSI/ESD- S1.1 Section 6.1.3 Frequency of Functional Testing “The wrist strap
system
|
should be tested
daily to ensure proper electrical value.”
|
|
Per ESD Handbook ESD TR20.20 Section 5.3.2.4.2 Additional User Wrist
Strap Testing “Proper
|
testing of the wrist strap includes the resistance of the groundable point on the end of the
|
cord, the cord itself, the resistor, the cord-to cuff snap
connector, the resistance of the
|
interface of the cuff, the cuff/wrist interface, and the
resistance of the person between the
|
wrist
and the hand that contacts the test electrode.”
|
|
“A
log should be maintained which verifies that personnel have tested their
personal
|
grounding devices.
(Wrist Straps and ESD Footwear)” (ANSI/ESD S20.20 Section 6.2.2.2
|
Personnel
Grounding Guidance)
|
|
The EMIT Dual Independent Footwear and Wrist Strap Tester is
available in three models:
|
Model
|
Voltage
|
Power
Adapter
|
|
50407
|
120
VAC
|
USA
|
|
50562
|
220
VAC
|
UK/ Asia
|
|
50413
|
220
VAC
|
None
|
|
|
Specifications
|
Rated
tester voltage:
|
12
VDC, 600 mA, (2.5 mm connector – center positive)
|
|
Relay contact rating:
|
1 A @ 30 VDC max
|
|
Temperature
range:
|
41đF – 104đF (5đC – 40đC)
|
|
Operating conditions:
|
Indoor use only at altitudes less than 6500 ft. (2 km).
|
Maximum relative humidity of 80% up to 88đF
(31đC) decreasing
|
linearly
to 50% @ 104đF (40đC).
|
Maximum relative humidity of 50% at 1 Gigohm
setting.
|
|
Pollution
degree:
|
2
per IEC 644
|
|