Clamp-On
Meter
|
Models
511, 512 & 514
|
|
Features
|
Standard size, full function clamp-on meters
|
1000AAC or 1000AAC/DC current
measurements
|
750 VAC or 1000VDC volt measurements
|
TRMS measurements (Models 512 and 514)
|
Resistance measurements to 4000Ω
|
Continuity with beeper below 40Ω
|
Frequency measurements from V and A
|
Diode test
|
1ms Peak function for fast capture of signals
|
Hold function to freeze readings
|
Push-button for easy ADC zeroing
|
Large, easy-to-read 4000-count display
|
42-segment analog bargraph
|
Includes test leads and soft carrying pouch
|
|
Applications
|
Commercial, industrial, residential and HVAC troubleshooting
|
Power panel, junction box and battery bank monitoring
|
AC or DC motor testing
|
Power plant troubleshooting
|
Electrical testing and troubleshooting on traditional and non-linear
loads, such as adjustable speed drivers and computers
|
|
Specifications
|
MODELS
|
511
(Average Sensing)
|
512
(TRMS)
|
514
(TRMS)
|
GENERAL
|
Digital
Display
|
3 ¾ digits LCD display, 4000-count
(max. reading 3999)
|
Analog
Display
|
Fast 42-segment analog bargraph display
|
Symbol
and Scale Range
|
Automatic according to range and input
signal
|
Sample
Rate
|
2 samples/sec for the digital display,
20 samples/sec for the analog bargraph
|
Power
Supply
|
9V, NEDA 1604 or 6F22 or 006P
|
Auto-Off
|
30 minutes
|
Jaw Opening
Size Ø
|
1.575 (40mm) facilitates 750MCM
cable or two 500MCM cables
|
Dimension
|
9.53 x 2.60 x 1.42 (242 x 66 x 36mm)
|
Weight
|
14.10 oz (400g) with batteries
|
ENVIRONMENTAL
|
Altitude
|
2167 ft (2000m) max.
|
Operating
Temperature
|
511/512: 32๐ to 104๐F (0๐ to 40๐C),
<80% RH, non-condensing
514: -14๐ to 122๐F (-25 to 50๐C), 80%RH, non-condensing*
|
Storage
Temperature
|
-14๐ to 140๐F (-25๐ to 60๐C),
<80% RH, battery removed
|
Pollution
Degree
|
2
|
SAFETY
|
Safety
Rating
|
EN 61010, 600V, CAT III, EN
61010, 1000V, CAT II
|
CE
Mark
|
Yes
|
*NOTE: If the meter is to be used below 32๐F
(0๐C), we suggest that the battery be
replaced to ensure proper results.
|