OxiTop BOD
Measurement Instrumentation
|
Pressure sensors for BOD testing and
measurements.
|
OxiTop® Control Biological Oxygen Demand (BOD)
Instrumentation is an advanced
|
version
of the successful OxiTop® BOD Instrumentation
system that uses software- controlled
|
functions and an infrared interface to
communicate with a handy controller, the OC 100.
|
This
BOD instrumentation system enables the simultaneous and grouped start, management,
|
storage
and tracking of 100 BOD measuring heads via the controller and allows them
|
to be tracked on a large display with graphic
evaluation. BOD measurement data can be
|
transferred
to the PC for evaluation and documentation via the AK-540/B Cable
|
(order no. 902842)and the communication program Achat OC (order no. 208990).
|
|
The
Biological Oxygen Demand (BOD) data can be called up at any time, even during
|
sampling, thus enabling checking of the samples
for errors. The display of the progress curve
|
allows
immediate detection of irregularities and interferences, such as having the
BOD value
|
set too high for the volume used or undesired
nitrification. BOD measurement corrections can
|
thus be made at an early stage. OxiTop®
Control BOD instrumentation offers you simple operation,
|
improved controllability, non-toxicity, and
measuring ranges of up to 4,000 mg/l BOD.
|
|
Specifications
|
Measuring
principle:
|
Respirometric (manometric)
|
Measured of:
|
BODn (oxygen
drift according to DIN 38409 T 52)
|
Pressure
range:
|
7.25
to 19.5 psi (500 to 1350 hPa(mbar))
|
Accuracy:
|
+/-1% of measured value. +/-7% of
measuring range
|
Resolution:
|
0.015
psi (1 hPa)
|
Display:
|
LED pilot lamps
|
Power
supply:
|
Lithium
batteries (260 mAh), 2 x type CR 2430 (3V)
|
Battery run time:
|
~ 2 years with normal use
|
Protection
class:
|
3
IEC 1010, EN61010 part 1
|
Protection type:
|
IP 54 DIN 40050
|
Admissible
measuring temperature:
|
68๐F +/-1.8 F (20๐C +/-1C)
|
Admissible sample temperature (when being filled)
|
59-68๐F (15-20๐C)
|
EMC
|
Emissions:
|
EN
50081-1, FCC Class A
|
Immunity:
|
EN 50082-2
|
Climate
class:
|
2,
VDI/VDE 3540
|
Ambient temperature:
|
Storage:
|
-13๐F to +149๐F (-25๐C to +65๐C)
|
Operation:
|
41๐F to +122๐F (5๐C to +50๐C)
|
Test
mark:
|
CE,
UL, CUL(UL/CSA)
|
Dimensions:
|
H:2.8in, dia. 2.8in (70 mm, dia. 70 mm)
|
Weight:
|
Approx.
3.4 oz. (95 g)
|
|
Options and Price List
|
208202 OxiTop®
Control 6
|
BOD
Measurement Instrumentation
|
BOD
measuring instrument for self-check, with controller OC100, 6 measuring units
with IR interface,
|
115 VAC, 50/60 Hz, and accessories.
|