Load Cell With Overload
Protection
|
Models
F50, F100
|
50 lb and 100 lb capacity
|
Overload protection to 5000 lb
|
Highly accurate
|
Temperature compensated
|
Rugged construction
|
|
Description
|
Michigan Scientific's
Load Cell With Overload Protection is ideal for compressive loading
applications
|
that require both high resolution measurements
up to 50 or 100 lb and overload protection up to 5000 lb.
|
These load cells are
typically used in manufacturing operations where large overload forces
exist. For
|
example, they are used to monitor bearing
pre-loads in machines that set bearing pre-loads for large
|
inertia parts. Both the F50
and F100 models provide one channel of data.
|
|
The F50 and F100
models are made of high grade aluminum material which provides excellent
resistance
|
to corrosion
and environmental conditions. Weatherproofing is available for applications operating
in
|
severe environmental
conditions. Temperature compensation of the transducers ensures stable output
|
throughout a wide
temperature range. In addition, the transducers are configured for easy
adaptation to
|
a variety
of applications.
|
|
Specifications
|
|
F50
|
F100
|
|
Maximum Load Capacity
|
5000 lbs (2300 kg)
|
5000 lbs (2300 kg)
|
|
Full Scale Load
|
50 lbs (23 kg)
|
100 lbs (45 kg)
|
|
Full Scale Output
|
2.0 mV/V +/-0.5%
|
|
Sensor
|
4 arm strain gage bridge
|
|
Nonlinearity
|
0.1% of full scale output
|
|
Hysteresis
|
0.1% of full scale output
|
|
Repeatability
|
0.05% of full scale output
|
|
Zero Balance
|
Within +/-1.0% of rated output at
zero load
|
|
Temperature Range, Compensated
|
75๐F to 200๐F (24๐C to 93๐C)
|
|
Temperature Effect on Zero
|
0.0015% reading/๐F
(0.0027% reading/๐C)
|
|
Temperature Range, Useable
|
-40๐F to 250๐F (-40๐C to 121๐C)
|
|
Excitation Voltage,
Maximum
|
10V DC or AC rms
|
|
Insulation Resistance, Bridge/Case
|
Exceeds 2000 MΩ @ 50VDC
|
|
Output Connector
|
PT02A-10-6P
|
|
Mating Connector
|
PT06E-10-6S (SR)
|
|