Viscosity Cups according to ASTM D
1200 (Ford)
|
Product
Description:
|
The process of flow through an orifice can often
be used as a relative measurement and
|
classification of viscosity. This measured kinematic viscosity is generally
expressed in
|
seconds of flow time which can be converted into
Centistokes using a viscosity disc
|
calculator. Viscosity Flow Cups are used for measuring the consistency of
paints,
|
varrishes and other similar
products.
|
Standards:
|
ASTM D 1200
|
Application/
application area’s:
|
Laboratory
|
Features:
|
A relatively deep well surrounding the top of the cup
serves to catch any overflow.
|
The design of the cup and orifice eliminable hard to
clean recesses.
|
The outside dimensions have been chosen to support the TQC stands.
|
TQC viscosity cups are made underline continuing
quality control procedures.
|
Each cup is provided with an engraved unique serial
number.
|
Standard
delivery:
|
Each viscosity cup comes with a hard plastic
storage case, with protective soft material on the inside.
|
Use:
|
According to the standard all measurements should be
made at 25๐C. Temperature drift
during the test should be kept to a minimum and should not exceed +/-0.2๐C. Adjust the temperature of the material to be
measured if necessary.
|
Select the proper orifice to be used from the specification
table, which depends on the expected viscosity range of the material to be
measured.
|
Once the viscosity cup is truly horizontal (this is best achieved
using a cup stand and bubble level), cover the exit orifice and fill the cup
making sure that the meniscus of the liquid is above the rim of the cup.
|
Using the glass draw plate, remove the meniscus into
the overflow ring and close the cup
|
The distance between the orifice of the flow cup and
the surface of the receiving sample has to be more than 100mm. Open the exit
orifice and remove the glass draw plate. Time between the removal of the
glass draw plate and the first break in the liquid’s flow is measured.
|
Technical
data:
|
Viscosity Cup
Type FR10
|
Cup: Stainless steel
|
Nozzle: Stainless steel,
fixed
|
Acc. to: ASTM D 1200
|
Weight: 556-558 gram*
|
Max. Width: 92 mm
|
Height: 74 mm
|
* (depending on orifice)
|
Article Number
|
Product Desar.
|
Ø Orifice (mm)
|
Viscosity Range (0Bt)*
|
Flow times (sec.)*
|
VF2041
|
No.1
|
2.1
|
10-35
|
55-100
|
VF2042
|
No.2
|
2.8
|
25-120
|
40-100
|
VF2043
|
No.3
|
3.4
|
40-220
|
30-100
|
VF2044
|
No.4
|
4.1
|
70-370
|
30-100
|
VF2045
|
No.5
|
5.8
|
200-1200
|
30-100
|
* For information purposes only; all approximate