The Fast and Robust Flue
Gas Measuring
|
Instrument for All
Important Parameters
|
testo 327-1 :
the basic instrument for heating constructors and gas fitters
|
Includes all basic functions such as combustive
efficiency, flue gas loss, O2, CO2, CO and flue draught
|
Robust and protected from impact with
Elastomer covering
|
Easy operation
|
Excellent handling thanks to easy-to-follow menus and
ergonomic housing
|
Stable readings in 30 sec.
|
The complete range of probes of testo 330 is compatible
|
Low weight (approx. 500 g)
|
An Overview of the instruments
functions
|
Easy-to-follow menu
|
4-line segment display
|
LED display illumination
|
Easy IR printout
|
Built-in condensate trap
|
TÜV-tested (๐C,
O2)
|
EN 50379 Part 2 for O2,
๐C, hPa
|
EN 50379 Part 3 for CO
|
Small Li-ion battery (1200 ma, battery life
5 h) chargeable in instrument or external charger
|
Fast probe connection with single probe
plug
|
Ambient CO measurement via flue gas probe
|
O2 dual wall measurement
(storable)
|
Separate air temperature measurement
|
CO measurement undiluted (storable)
|
Draught measurement
|
Spare battery chargeable in instrument or
separately
|
8 fuels
|
IP 40
|
Technical Data
|
327-1
|
Temperature measurement:
|
Measuring
range:
|
-40
to +600๐C
|
Accuracy:
|
+/-0.5๐C (0 to +99.9๐C)
+/-% of m.v. (from +100๐C)
|
Resolution:
|
0.1๐C
|
Draught/ pressure measurement:
|
Draught:
|
+/-40 hPa
|
Accuracy:
|
+/-0.02
hPa (-0.50 to +0.60 hPa)
+/-0.03
hP (+0.61 to +3.00 hPa)
1.5%
of m.v. (+3.01 to +40 hPa)
|
Resolution:
|
+/-0.01 hPa (fine draught
optionL0.001 hPa)
|
Determination of efficiency (ETA)
|
Measuring
range:
|
0
to 120%
|
Resolution:
|
0.1%
|
Exhaust loss:
|
Measuring
range:
|
0
to 99.9%
|
Resolution:
|
0.1%
|
O2 measurement:
|
Measuring
range:
|
0
to 21 Vol.%
|
Accuracy:
|
+/-0.2 Vol.%
|
Resolution:
|
0.1%
|
Adjustment time t90:
|
approx. 40 sec.
|
CO2 recording:
|
Display
range:
|
0
to CO2max
|
Accuracy:
|
+/-0.2 Vol.%
|
Resolution:
|
0.01
Vol.%
|
Recording:
|
dig.
Calculation from aus O2
|
Adjustment
time t90:
|
approx.
40 sec.
|
CO measurement:
|
Measurement range:
|
0 to 4000 ppm
|
Accuracy:
(H2 content <10%)
|
+/-20
ppm (up to 400 ppm) +/-5% of m.v.(up to 1000 ppm)
+/-10%
of m.v. (up to 4000 ppm)
|
Resolution:
|
1 ppm
|
General technical data:
|
Weight:
|
approx.
500 g
|
Dimensions:
|
216 x 68 x 47
|
Transport/
storage temperature
|
-20
to +50๐C
|
Ambient temperature
|
-5 to +45๐C
|
Power
supply:
|
Li-ion
rech. battery
|
Battery
life:
|
>5h
|
Warranty:
|
24
months on instrument, probes and measurement cells
12
months on thermocouple and battery
(does
not apply to wearing parts)
|