Static control for
hazardous areas
|
Static Dissipative Footwear Test Station
|
- Upper
Level Resistance Options (1 x 108 or 1 x 109 Ohms)
|
- Optional
Interlock Relay Version
|
|
- Yearly
Calibration Service
|
- IP65
Industrial Standard Enclosure
|
The
Sole-Mate is a user friendly device that is designed to test the condition of
static
|
dissipative
footwear prior to entering safety critical hazardous areas exposed to
|
potentially explosive atmospheres.
ÿ
|
International Standards recommend regular testing of static
dissipative footware.
|
The Sole-Mate provides a time efficient and cost effective
method of ensuring
|
personnel are wearing static
dissipative shoes that are fit for purpose.
ÿ
|
The
Sole-Mate tests the condition of the shoes by measuring the resistance of the
|
electrical loop through the operator and their footwear. If the
resistance of the shoes
|
is too
high, the Sole-Mate will indicate that the shoes have failed the test via a
red
|
lamp and buzzer alarm. If the shoes pass the test a green lamp
will indicate to the
|
operator that the shoes are fit for purpose.
ÿ
|
Additionally, users can specify if they wish to interlock the
tester with audible alarms
|
or entry doors into hazardous areas so that personnel not
wearing suitable footwear
|
cannot enter the hazardous areas. All
Sole-Mate units are supplied with 6ft cable and
|
US style plug. (UK unit supplied with 3m cable to
wire into a mains supply).
ÿ
|
Relevant International Standards
|
Based on user preference, the Sole-Mate can be set
to measure upper level resistance
|
As
defined by appropriate standards below:
|
- EN ISO 20345 – 1 x 109
ohm
|
ÿ |
- CLC/TR 50404 – 1 x 108
ohm
|
ÿ |
- ASTM F2413-05 (Type I) – 1 x
108 ohm
|
ÿ |
- ASTM F2413-05 (Type II) – 1
x 109 ohm
ÿ
|
ÿ |
Sole-Mate VESF50/ IR Interlock Versions:
|
Version
includes volt freeÿ relay contact
to interlock with door entry mechanism, alarm or
|
data collection system.
ÿ
|
Calibration Test Unit VESF59 & VESF59/A
|
The user
can ensure that the Sole-Mate is measuring the desired resistance threshold
|
on-site using the optional Calibration Test Unit.
ÿ
|
National Standard Calibration Service
|
The
Calibration Test Unit may be returned to your supplier for yearly checking
using
|
equipment traceable to national standards. A new calibration
certificate will be issued.
ÿ
|
Alternative Versions
|
It may
be possible to supply the Sole-Mate set to alternative measurement settings,
by
|
special order.
ÿ
|
Part Number
|
VESF50
|
1 x 109 240Vac
|
ÿ |
VESF50/IR
|
1 x 109
240Vac with Interlock Relay Output
|
ÿ |
VESF50A
|
1 x 108
240Vac
|
ÿ |
VESF50A/IR
|
1 x 108
240Vac with Interlock Relay Output
|
ÿ |
VESF50U/110
|
1 x 109
110Vac US plug version
|
ÿ |
VESF59
|
1 x 109
Calibration Test Unit
|
ÿ |
VESF59/A
|
1 x 108
Calibration Test Unit
|
ÿ |
* For
110Vac supply, add/110 to part number
|
|
|
|
|