PORTABLE GAS DETECTOR
|
XP-3000 SERIES
|
|
Reliable
and flexible lightweight portable gas detector
|
For
environmental safety and spot check applications
|
|
Typical Applications
|
Oil
& Gas, Power Stations, Petrochemical, Chemical Plants, Boiler Rooms,
Automotive
|
|
Combustible
gas detector
|
XP-3110
|
100%
LEL
|
|
For
measurement of combustible gas concentration of 0-10/0-100%LEL. Suitable for
monitoring
|
a risk of
explosion. Built-in correction factors for up to 5 flammable gases. (factory
option)
|
Ex:
Methane, Isobutane, Propane, Ethanol, Hydrogen,
Acetylene, etc.
|
|
High
concentration gas detector
|
XP-3140
|
100vol%
|
|
For
measurement of high concentration gas up to 100vol%. Suitable for inspecting
the amount
|
of gas
remaining in tanks.
|
Ex:
Methane, Hydrogen, Helium, Argon, Butane, Carbon dioxide, etc.
|
|
High
sensitivity explosive gas detector
|
XP-3160
|
PPm
|
|
High
sensitivity detector with 0-500ppm measuring range (Standard). Best suited
for measuring
|
toxic and
combustible gases in the ppm range. Built-in correction factors for up to 5
flammable
|
gases. (factory
option)
|
Ex:
Methane, Isobutane, Propane, Ethanol, Hydrogen,
Acetylene, Toluene, o-Xylene, Benzene, etc.
|
|
Oxygen
indicator
|
XP-3180
|
25.0vol%
|
|
Extractive
oxygen concentration indicator. Convenient for measuring oxygen concentration
on site
|
where sampling
is difficult.
|
|
Multi-Gas
detector
|
XP-3118
|
100%LEL/
25.0vol%
|
|
Simultaneous
monitoring of combustible gas and oxygen concentration. Perfect for
compliance
|
work, safety
and environmental monitoring.
|
Ex:
Methane, Isobutane, Propane, Ethanol, Hydrogen,
Acetylene, etc.
|
|
Specifications
|
Model
|
XP-3110
|
Gas
Detected
|
Combustible
gases and vapors (specify gas detected)
|
Detection Principle
|
Catalytic combustion
|
Sampling
Method
|
Extractive
|
Detection Range
|
0 to 100% LEL
|
Indication
Accuracy
(Under
identical conditions)
|
+/-5%
of full scale
|
Alarm Set Value
|
20% LEL
|
Display
|
LCD
digital (with backlight)
Digital
display: 0-100% LEL
Digital
bar display: Auto range changeover
0-10%
LEL (Lrange)
0-100%
LEL (Hrange)
|
Alarm Indication
|
Gas alarm: Intermittent buzzer, Red lamp flashing
Error alarm: Buzzer, Red lamp flashing, LCD display
|
Explosion-Proof
Structure
|
Exibd IIC T3
(TIIS)
Ex
II2G Exdib IIB T4 Gb (ATEX)
Exdib IIB T4 Gb
(IECEx)
Class
I, Zone 1, AEx d ib IIB
T4 Hazardous Locations (UL)
|
Operation Temperature
|
0 to +40ºC
|
Power
Source
|
4
x AA alkaline dry battery
|
Battery Life
|
Up to 20 hours
Battery life time is subject to environmental and storage
conditions.
|
Dimensions
|
W82
x H162 x D36 mm
|
Weight
|
Approx. 450g (16oz.) (excluding batteries)
|
Standard
Accessories
|
Soft
case, 4 x AA alkaline dry battery, Gas sampling hose (1meter),
Probe
with filter/moisture trap
|
Optional Accessories
|
2-30 meter gas sampling hose, Gas dilution probe,
Data download software (CD-ROM software and USB cable)
|
|
|
|
|
|
|