The
Fluke 568 Ex
|
Intrinsically
Safe Infrared Thermometer
|
|
Product
Highlights
|
With a rugged, easy-to-use, ergonomic
design, the Fluke 568 Ex can stand up to tough industrial,
|
electrical, and
mechanical environments.
|
§ Meets
intrinsically safe certifications in Class I Div I
and Div 2 or Zone 1 and 2 hazardous environments
from recognized safety agencies around the world
|
§ Measure
-40°C to 800°C (-40°F to 1472°F)
|
§ Conductive
Case for carrying the IR thermometer safely into hazardous area
|
§ Easily
access advanced features with the soft-key buttons and graphical display
|
§ Measure
small objects from further away, with a distance-to-spot ratio of 50:1
|
§ Compatible
with mini-connector K-type thermo-couple (KTC) probe
|
§ Confidently
measure a wide variety of surfaces with the adjustable emissivity feature,
including a built-in material table
|
§ Capture up
to 99 points of data
|
§ Confidently
troubleshoot equipment with +/-1% measurement accuracy
|
§ Versatile
interface with five languages from which to choose
|
§ Two-year
warranty
|
|
Specifications
|
Infrared
temperature range
|
-40°C to 800°C (-40°F to 1472°F)
|
Infrared
accuracy
|
<
0°C (32°F): +/-
(1.0°C (+/-2.0°F) +0.1°/1°C or °F);
≥
0°C (32°F): +/-1%
or +/-1.0°C (+/2.0°F),
Whichever
is greater
|
Display
resolution
|
0.1°C/ 0.1°F
|
Infrared
spectral response
|
8
µm to 14 µm
|
Infrared
response time
|
<
500 ms
|
Thermocouple
Type-K
input
temperature range
|
-270°C to 1372°C (-454°F to 2501°F)
|
Thermocouple
Type-K
input
accuracy
|
<-40°C: +/-(1°C + 0.2°/1°C)
≥
-40°C: +/-1%
or 1°C,
whichever is greater
<-40°F: +/-(2°F + 0.2°/1°F)
≥
-40°F: +/-1%
or 2°F,
whichever is greater
|
D:S
(distance to measurement spot size)
|
50:1
|
Laser
sighting
|
Single-point
laser
|
Minimum
spot size
|
19
mm (0.75 in)
|
Emissivity
adjustment
|
By
built-in table of common materials or digitally adjustable
from
0.10 to 1.00 by 0.01
|
Data
storage
|
99
points
|
Hi/Low
alarms
|
Audible
and two-color visual
|
Min/Max/Avg/Dig
|
Yes
|
Display
|
Dot
matrix with function menus
|
Backlight
|
Two
levels, normal and extra bright for darker environments
|
Trigger
lock
|
Yes
|
Switchable
Celsius and Fahrenheit
|
Yes
|
Power
|
2
AAA/LR03 type-approved Batteries (For a list of type-approved batteries,
refer to Product Safety Instructions)
|
Battery
life
|
4
hours with laser and backlight on; 100 hours with laser and backlight off, at
100% duty cycle
|
Operating
temperature
|
0°C to 50°C (32°F to 122°F)
|
Storage
temperature
|
-20°C to 60°C (-40°F to 140°F)
|
Bead
thermocouple
Type-K
range
|
-40°C to 260°C (-40°F to 500°F)
|
Bead
thermocouple
Type-K
accuracy
|
+/-1.1°C (2.0°F) from 0°C to 260°C (32°F to 500°F),
typically
within 1.1°C (2.0°F)
from
-40°C to 0°C (-40°F to 32°F)
|
|
Ordering
information
|
FLUKE-568
Ex Intrinsically Safe Infrared Thermometer
|
Included equipment
|
§ K-type
thermocouple bead probe
|
§ Conductive
IS hard carrying case
|
§ User’s
manual
|