COATING THICKNESS POCKET GAUGE - MPOR
|
|
Coating
thickness pocket gauge MPOR is a pocket device with integrated USB for
appropriate and quick
|
coating thickness
measurement on all metals effectively. Its structure and permeability have
less effect on
|
measurement result when
compared with other devices. Coating thickness pocket gauge MPOR has two
|
remarkable
measuring methodology in agreement with measurement regulation IMO PSPC
(90/10-Rule) and
|
SSPC.PA2.
Coating thickness pocket gauge MPOR is easy to carry as it is insubstantial
and has resilient
|
design which is highly
appreciated in the market.
|
|
MODELS
|
· PERMASCOPE MPOR:
Probe integrated in the measuring instrument for single-handed operation
|
· PERMASCOPE
MPOR_FP: Probe with cable (80 cm; 31.5) permanently connected to the
instrument,
|
for measurements on various specimen
shapes
|
|
FEATURES
|
· Paint, varnish or
plastic coatings on aluminium, copper or brass
|
· Anodized coatings
on aluminium
|
|
Evaluation
|
Statistics:
|
Display
of mean value, standard deviation, MIN, MAX and number of measurements per
block
|
PC
software included in the scope of supply:
|
PC
software FISCHER DataCenter with the following
functionality: Transferring and archiving measurement data, comprehensive
statistical and graphical evaluations, easy creation and printing of
inspection reports.
|
|
Measurement Functions
|
Block
size:
|
Adjustable
between 2 and 20 single readings per block
|
Tolerance
limits:
|
Adjustable,
depending on the selected measuring mode
|
Offset
value:
|
In
the standard mode, the freely adjustable offset value is deducted
automatically from the measured value. Thus, one obtains the thickness of the
top coating if for instance the interim coating is khown.
|
Calibration:
|
Factory
calibration
|
Each
individual instrument is factory calibrated at several reference points with
the greatest care to ensure the highest possible degree of trueness.
|
Corrective
calibration (Adjustment)
|
Adaptation
to the substrate material and the shape of the specimen and to a thickness
value using a calibration foil.
|
Simple
Calibration
|
Adaption
to the coating and substrate material in one step using a coated reference
part with a coating thickness higher than 200 µm (7.87 inches). Nevertheless,
this kind of calibration supplies only a lower accuracy as specified in the
sections Trueness and Repeatability Precision.
|
|
General Features
|
Measuring
method:
|
Magnetic
induction method (ISO 2178, ASTM D7091, Measurement of non-magnetic coatings
on magnetic substrates)
|
Probe:
|
Probe
tip radius: 2 mm (78 mils); Probe tip material: Hard metal
|
Data
memory:
|
Max.
1,000 individual readings; the contents of the memory is retained even
without batteries
|
Measuring
frequency:
|
More
than 70 measurements per minute
|
Display:
|
Graphic
display, in addition to the measurement reading the mean value and the
standard deviation or the number of measurement reading can also be
displayed. LCD display on the top side of the instrument, e.g. for reading
the measurement value for measurement overhead
|
Display
limit value violation:
|
Acoustically
through 2 short beeps and visually with a red lit LED
|
Languages:
|
Many
different display languages are selectable: German, English and several other
European and Asian languages
|
USB
port:
|
2.0
compatible, mini type B socket, for connecting a PC
|
Data
transfer:
|
Single
readings, mean values, group separator
|
Admissible
ambient temperature range during operation:
|
0
+40๐C (+32
+104๐F)
|
Weight
(incl. batteries):
|
MPOR:
137 g (4.8 oz)
MPOR-FP:
184 g (6.5 oz)
|
Power
supply:
|
2
Batteries, LR6, AA, 1.5V
|