MITECH
MT180 ULTRASONIC THICKNESS GAUGE
|
|
|
|
Product
Description
|
|
The
Mitech MT180 is a multi-mode ultrasonic thickness
gauge. Based on the same operating
|
|
principles
as SONAR, the instrument is capable of measuring the thickness of various
materials with
|
|
accuracy as high
as 0.1/0.01 millimeters.
|
|
|
|
The
multi-mode feature of the gauge allows the user to toggle between pulse-echo
mode (flaw
|
|
and pit
detection), and echo-echo mode (eliminate paint or coating thickness).
|
|
|
|
· Multi-mode:
Pulse-Echo mode and Echo-Echo mode.
|
|
· Capable of
performing measurements on a wide range of material, including metals,
plastic, ceramics, composites, epoxies, glass and other ultrasonic wave
well-conductive materials.
|
|
· Transducer
models are available for special application, including for coarse grain
material and high temperature applications.
|
|
· Probe-Zero
function, Sound-Velocity-Calibration function
|
|
· Two-Point
Calibration function.
|
|
· Single
point mode and Scan mode. Seven measurements readings per second in single
point mode, and sixteen per second in Scan Mode.
|
|
· Coupling
status indicator showing the coupling status.
|
|
· Units:
Metric/Imperial unit selectable.
|
|
· Battery
information indicates the rest capacity of the battery.
|
|
· Auto sleep
and auto power off function to conserve battery life.
|
|
· Optional
software to process the memory data on the PC.
|
|
|
|
Product
Specifications
|
|
· Display:
4.5 digits LCD with EL backlight.
|
|
· Range:
Pulse-Echo mode: (0.65 ~ 600)mm (in Steel).
|
|
· Echo-Echo
mode: (3 ~ 30) mm for MT180, (3 ~ 60) mm for MT190.
|
|
· Sound
Velocity Range: (1000 ~ 9999) m/s.
|
|
· Resolution:
0.1mm/0.01mm
|
|
· Accuracy:
+/-(0.5% Thickness +0.01) mm, depends on materials and conditions
|
|
· Memory for
up to 20 files (up to 99 values for each file) of stored values.
|
|
· Power
Source: Two AA size, 1.5 Volt alkaline batteries. 100 hours typical
operating time (EL backlight off).
|
· Communication:
USB1.1
|
|
· Dimensions:
150 mm x 74 mm x 32 mm
|
|
· Weight:
245 g
|
|
|
|
Operating
Conditions
|
|
Operating Temperature: -20๐C ~ +60๐C
|
|
Storage
Temperature: -30๐C ~ +70๐C
|
|
Relative Humidity : ≤90%
|
|
The
surrounding environment should be free of vibration, strong magnetic fields,
corrosive materials and heavy dust.
|
|