Dual Independent Footwear Tester
|
Installation, Operation and Maintenance
|
|
Description
|
The
EMIT Dual Independent Footwear Tester is a 6-state touch tester designed for
fast and
|
frequent testing
of ESD personnel footwear. This tester can be used to verify that the ESD
|
footwear resistance
circuit is within the proper limits. By depressing the test button once, the
|
Dual
Independent Footwear Tester tests the resistance path limits of both worn ESD
footwear
|
independently within
three seconds. It can be setup to test a 100 kilohms
(10E5)-1 megohm
|
(10E6)
circuit (foot grounders) or a 10 megohms (10E7) 1
gigohm (10E9) circuit (dissipative shoes).
|
|
This
unit can be used as one of the tools to fulfill the ANSI/ESD S20.20 Section
6.1.3.2 Compliance
|
Verification
Plan. Verification should include routine checks of the Technical
Requirements of
|
the Plan.
The Dual Independent Footwear Tester incorporates a unique dual test circuit
design
|
which improves
test accuracy.
|
|
The EMIT Dual Independent Footwear Tester is available in two
models:
|
Model
|
Voltage
|
Power
Adapter
|
|
50404
|
120
VAC
|
USA
|
|
50412
|
N/A
|
Sold
separately, see web site
|
|
|
Packaging
|
1
Dual Independent Footwear Tester
|
1
Dual Foot Plate
|
1
Power Adapter ŢŢ (50404 only)
|
1
Stereo Plug to Stereo Plug Cord
|
1
Banana Plug to Ring Terminal Cord
|
1
Certificate of Calibration
|
|
Specifications
|
Operating
Voltage:
|
12
VDC
|
|
Test Switch Voltage:
|
5 VDC @ open circuit
|
|
Wrist
Strap and Footwear Test Voltage:
|
12
VDC @ open circuit
|
|
Test Current:
|
Limited by resistors and varies on the test range setting (100
kilohms 1 gigohm)
|
|
Relay
Contact Rating:
|
1A
@ 30 VDC max
|
|
Temperature Range:
|
41๐F
- 104๐F
(5๐C
- 40๐C)
|
|
Operating
Conditions:
|
Indoor
use only at altitudes less than 6500 ft. (2 km)
|
Maximum
relative humidity of 80% up to 88๐F (31๐C)
|
decreasing
linearly to 50% @ 104๐F (40๐C)
|
Maximum
relative humidity of 50% at 1 Gigohm setting
|
|
Pollution Degree:
|
2 per IEC 644
|