Fluke 345
|
Power Quality Clamp
Meter
|
The ideal meter for
commissioning and troubleshooting modern electrical loads
|
AC/DC current: Clamp-on measurement
of ac current up to 1400 A rms and dc current up to
2000 A without breaking the circuit
|
Highest
safety rating: 600 V CAT IV rated for use at the service entrance
|
Accurate in noisy
environments: Even with distorted waveforms present on electronic loads with
low-pass filter
|
Data
logging: Identify intermittent faults by logging any power parameters
for minutes or months, including harmonics
|
Verify batteries: Direct measurement of
dc ripple (%) for battery and dc systems
|
Troubleshoot
harmonics: Analyze and log harmonics digitally or graphically
|
Inrush current: Capture and analyze
nuisance tripping, from 3 seconds to 300 seconds
|
Easy to
use: Easily confirm instrument setup with large backlit color
display of waveforms and trends
|
3-Phase power: Built in capability
for balanced loads
|
View
graphs and generate reports: With included Power Log software
|
|
Applications
|
Set up and troubleshoot variable
frequency drives and UPS systems –
Verify correct operation
|
by measuring key parameters.
|
Harmonics
measurements – Uncover harmonic
issues that can damage or disrupt critical equipment
|
Inrush capture – Check start-up
current where spurious resets or nuisance circuit breaker tripping
|
occurs
|
Load studies – Verify electrical
system capacity before adding loads
|
|
General Specifications
|
Display
|
Color
transmissive LCD 320 x 240 pixels (70 mm diagonal)
with 2 level backlight
|
|
Power supply
|
Battery
type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6
|
Battery life typically
|
>
10 hours (backlight on full)
|
|
>
12 hours (backlight reduced)
|
Battery Eliminator BE345
|
Input
|
110
V/230 V, 50/60 Hz
|
Output
|
15
V dc, 300 mA
|
|
Ambient conditions (For indoor use only)
|
Reference conditions
|
All
accuracies stated at 23๐C +/- 1
๐C
(73.4 ๐F
+/-1.8 ๐F)
|
Operating temperature
|
0 ๐C
to 50 ๐C (32 ๐F
to 122 ๐F)
|
Temperature coefficient of
current
|
≤
+/-0.15% of rdg per ๐C
|
Temperature coefficient of
voltage
|
≤
+/-0.15% of rdg per ๐C
|
Maximum relative humidity
|
80%
for temperatures up to 31๐C (87๐F)
decreasing linearly to 50% relative humidity at 40๐C
(104๐F)
|
Maximum operating altitude
|
2000
m
|
|
Electrical safety
|
Safety
IEC 61010-1 600 V CAT IV, double or reinforced insulation, pollution degree 2
|
Protection
IP40; EN60529
|
Maximum safe working voltages
|
Current measurement
|
600
V ac rms or dc between uninsulated
conductor and ground
|
Voltage measurement
|
600
V ac rms or dc between either
input terminal and ground, or 825 V between energized phase voltages
(delta power config.)
|
|
EMC
|
Emission
|
IEC/EN
61326-1:1997 class B
|
Immunity
|
IEC/EN
61326-1:1997
|
|
Mechanical
|
Dimensions (length x width x
depth)
|
300
mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
|
Weight including batteries
|
820
g/ 1.8 lb
|
Jaw opening
|
60
mm
|
Jaw capacity
|
58
mm diameter
|
Cleaning
|
The
unit can be cleaned with an Isopropanol impregnated
cloth. Do not use abrasives or other solvents.
|