  Top » Catalog » Maintenance/Engineering Instrume » Calibrator » CA71 My Account  |  Cart Contents  |  Checkout   
Categories
Health Instrument-> (21)
Laboratory Instrument-> (94)
Maintenance/Engineering Instrume-> (248)
  Calibrator (19)
  Cenetering Head (3)
  Clamp Meter (21)
  Holiday Detector (13)
  Insulation/Resistance Tester (10)
  Laser Alignment (2)
  LCR Meter (3)
  Leak Detector (5)
  Multimeter (44)
  Steel Stamp (2)
  Stroboscope (12)
  Tachometer (22)
  Thermal Imager (7)
  Torque Tester/Wrench (7)
  Transmission Tester (10)
  Vibration Meter (14)
  Yoke (8)
Measurement Instrument-> (466)
Process Insrument-> (467)
Safety Intrument-> (273)
Weigh Scale and Load Cell (62)
Manufacturers
What's New? more
Charged Plate Monitor "Trek" Model 156A
Charged Plate Monitor "Trek" Model 156A
$5,333.32
Quick Find
 
Use keywords to find the product you are looking for.
Advanced Search
Tell A Friend
 
We'd love it if you tell a friend about us Just enter their email address and click the envelope (you can also add a messege on the next page).
Information
Shipping & Returns
Privacy Notice
Conditions of Use
Order & Payment
Promotions
Contact Us
SSL Certificate
Free SSL Secured By StartCom
Portable Calibration "Yokogawa" Model No CA71
[CA71]
$1,775.00

 

 

 

Model CA51/ CA71

 

HANDY CAL calibrator

 

The CA51/CA71 HANDY CAL calibrators are comprehensive generating/measuring instruments

 

for all your calibration and equipment checking needs at maintenance sites. The CA51/CA71

 

can simultaneously generate and measure voltage, current, TC, RTD and pulse signals, thus you

 

don’t need to prepare many instruments. In addition, the incorporated rotary switches of good

 

repute enable operations so smooth that an incorrect measurement caused from erroneous

 

operations can be prevented.

 

 

 

General Specifications

 

Parameter

Specification

SOURCE unit response time

Approximately 1 second (time between start of voltage change and when voltage enters accuracy range)

 

SOURCE unit voltage limiter

Approximately 32 V

 

SOURCE unit current limiter

Approximately 25 mA

 

Divided output (n/m) function

Output = setting x (n//m) n=0 to m; m=1 to 19; n≤ m

 

Auto-step output function

N value sent automatically when n/m function is selected

(two options: approximately 2.5 seconds/step or approximately 5 seconds/step)

 

Sweep function

Sweep time (two options: approximately 16 seconds or approximately 32 seconds)

 

Memory function

50 sets of data (generated and measured values are stored as value sets with

the same address (up to 50 sets of data can be stored)

 

MEASURE unit maximum input

Voltage terminal: 300V DC/AC

Current terminal: 120 mA DC

 

Current terminal input protection

Fuses: 125 mA/250 V

 

MEASURE unit ground voltage

Maximum 300 V AC

 

Measurement display updating rate

Approximately once per second

 

Serial interface

Enables when communication cable (RS-232) is connected;

sold separately as optional accessory (CA71 only)

 

Display

Segment LCD (approximately 76 mm x 48 mm)

 

Backlight

LED backlight; auto-off after one minute (from when LIGHT key is turned on)

 

Power supply

Four AA-size (LR6) alkaline batteries, or special AC adapter (sold separately)

 

Battery life

Measurement off, output 5 V DC/10 kΩ or greater: Approximately 40 hours

Simultaneous signal generation/measurement, output 5 V DC/10 kΩ or greater:

Approximately 20 hours

Simultaneous signal generation/measurement, output 20 mA/5 V: Approximately 12 hours

(using alkaline batteries, with backlight off)

 

Consumed power

Approximately 7 VA (using 100 V AC adapter)

 

Auto-power-off function

Approximately 10 minutes (auto-power-off can be disabled through a DIP switch setting)

 

Applicable

standards

Standard safety

IEC61010-1, EN61010-2-031

 

EMC

Emission

EN61236-1 Class B, EN61000-3-2, EB61000-3-3

EN55011: Group1, Class

 

Immunity

EN61326 Annex B

 

Insulation resistance

Across input terminal and output terminal, 500V DC, 50 MΩ or greater

 

Withstand voltage

Across input terminal and output terminal, 3.7 kV AC, for one minute

 

Operating temperature and humidity ranges

0 to 50C, 20 to 80% RH (no condensation)

Storage temperature and humidity ranges

-20 to 50C, 90% RH or less (no condensation)

External dimensions (WHD)

Approximately 190 x 120 x 55 mm

 

Weight

Approximately 730 g (including batteries)

 

 

This product was added to our catalog on Monday 20 December, 2010.
Reviews
Shopping Cart more
0 items
Manufacturer Info
Yokogawa
Other products
Notifications more
NotificationsNotify me of updates to Portable Calibration "Yokogawa" Model No CA71
Tell A Friend
 
Tell someone you know about this product.
Reviews more
Write ReviewWrite a review on this product!
Languages
Thai English
Currencies
Credit card accepted




Advertisement

Nanomachinery Co., Ltd.
4, Soi Petchkasem 100 ,Phetchkasem Rd. ,Bangkaenue ,Bangkae ,Bangkok, 10160, THAILAND.
Tel : 086-322-6876 ,02-421-9927 ,Fax : 02-809-2591 E-mail : pongthorn@nano-machinery.com
Copyright © 2005 Nano Machinery