Lexxi T1660
|
|
TDR
Time Domain Reflectometer/ Network Analysis/ Cable Test
|
|
|
|
Radiodetections Lexxi T1660 provides an unrivalled combination of
performance, usability and economy. Radiodetection
|
|
has
created Lexxi T1660 by taking the easy-to-hold
ergonomics familiar to users of the Riser Bond Model 1550 and
|
|
Bicotest Lexxi T810 and installing a unique TDR engine and a 3.5
color back-lit display.
|
|
|
|
The result is a cable tester whose 1% distance accuracy and
resolution gives technicians the tool they need to find faults quickly and
accurately. Added to this is the Lexxi T1660s
great value that allows more technicians to be equipped.
|
|
|
|
The
Lexxi T1660 is suitable for analyzing all metallic
cables consisting of a least two metallic elements, one of which can be
|
|
the armouring or the screen. Cable types include CATV,
twisted pair telecom, Ethernet and even LV power cables.
|
|
The
Lexxi T1660 is shipped with a set of 100Ω crocodile
clip Twisted Pair connection cables as standard. A range of
|
|
optional plug-in
modules make it adaptable to the requirements of a wide variety of industries
and applications, with the Blocking Filter module allowing safe analysis of
live 3-phase mains cables. Radiodetections Lexxi T1660 offers innovation
|
|
and economy,
enabling a step-change in productivity.
|
|
|
|
Features
|
§ Large,
color display
|
|
§ 1%
fault location accuracy
|
|
§ 0.5 m dead
zone
|
|
§ 6
km, 19000 maximum range
|
|
§ 7 m, 23
minimum display range
|
|
§ 11
range settings
|
|
§ Operates
from Alkaline or NiMH rechargeable batteries
|
|
§ 12
hours typical battery life time (alkaline)
|
|
§ User
selectable Power Down time
|
|
§ Selectable
cable impedance
|
|
§ VoP
adjustable from 1% to 99%
|
|
§ 100Ω
Twisted Pair Alligator Clip cables included as standard
|
|
§ Optional
modules, including Category IV mains Blocking Filter, for twisted pair,
coaxial and power
|
|
cable
use make the Lexxi T1660 suitable for multiple
industries and applications
|
|
|
|
Table of Specifications
|
Notes
|
Ranges
|
7,
15, 30, 60, 120, 250, 500, 1000, 2000, 3000, 6000
20,
50, 100, 200, 400, 800, 1600, 3200, 9400, 10000, 20000
|
Meters
Feet
|
Range
Selection
|
Manual
range control
|
Accuracy
|
1%
of selected range*
|
Display
|
328
x 256 pixel 3.5 color backlit LCD
|
Resolution
|
Approx.
1% of range
|
Velocity
Factor, VoP
|
Adjustable
from 1% to 99%
|
Output
Pulse
|
5V
peak to peak
|
Into
open circuit
|
Output
Impedance
|
Selectable
25, 50, 75 & 100 ohms
|
Output
Pulse Width
|
3ns
to 3ms
|
Automatic
with range
|
Scan
Rate
|
2
scans/second
|
Batteries
|
Six
AA (LR6/R6) Alkaline or NiMH cells
|
Battery
Life
|
12
hours typical, continuous operation
|
Alkaline
batteries
|
Voltage
Protection
|
600V
AC Category III, 300V AC Category IV
250V
AC
|
Lexxi T1660
with Mains Blocking Filter
Lexxi T1660
with all other connectors and
Plug-In
Module options
|
Power
Down
|
Selectable
1, 3, 5, 10, 15 minutes or disabled
|
Operating
Temp.
|
-10° to 50°C, 14° to 122°F
|
Storage
Temp.
|
-20° to 70°C, -4° to 158°F
|
Dimensions
|
250
x 100 x 55 mm, 9.8 x 4 x 2.2
|
Weight
|
600g,
1.3lb
|
Standards
|
EMC
BS/EN 61326-1
|
Water/
Dust Proof
|
IP54
|
|
|
|
|
|