   Portable IR Calibrators 
   | 
 
 
  | 
     
   | 
 
 
  | 
   BX-500
  Portable IR Calibrators are used for calibrating long distance Infrared
  Thermometer, 
   | 
 
 
  | 
   which are
  designed as handheld and small calibrations. 
   | 
 
 
  | 
     
   | 
 
 
  | 
   Whether youre using in-line or handheld infrared pyrometers,
  you need  high performance 
   | 
 
 
  | 
   calibration standard to verify
  accuracy. Portable IR Calibrator provides a stable black body 
   | 
 
 
  | 
   target for calibrating non-contact IR
  thermometers up to 500°C. 
   | 
 
 
  | 
     
   | 
 
 
  | 
   The
  portable IR calibrator features a large temperature controlled blackbody
  target with a 
   | 
 
 
  | 
   diameter
  of 2.25 (57 mm), which offers a wide field of view area for optical
  variations in IR 
   | 
 
 
  | 
   thermometers. With an
  emissivity of 0.95, the isothermal target can be controlled in set-point 
   | 
 
 
  | 
   increments of 0.1°
  from 50°C to 500°C. 
   | 
 
 
  | 
     
   | 
 
 
  | 
   For even higher precision, a contact calibration well is
  located directly behind the blackbody 
   | 
 
 
  | 
   surface. Using an optional digital RTD
  thermometer and calibrated secondary probe,  
   | 
 
 
  | 
   accuracies of 
  +/-0.1°C can be achieved 
   | 
 
 
  | 
     
   | 
 
 
  | 
   FEATURES: 
   | 
 
 
  | 
   1.    
  Easily certify IR pyrometers to 500°C/ 932°C 
   | 
 
 
  | 
   2.    
  Large 2.25 (57 mm) blackbody target 
   | 
 
 
  | 
   3.    
  RTD (Resistance Thermometer Detector)
  reference well for high precision 
   | 
 
 
  | 
     
   | 
 
 
  | 
   SPECIFICATIONS: 
   | 
 
 
  | 
     
   | 
  
   BX-500 
   | 
 
 
  | 
   Temperature
  Range 
   | 
  
   50°C
  to 500°C/ 122°F to 932°F 
   | 
 
 
  | 
   Accuracy 
   | 
  
   +/-0.5°C
  @100°C/ +/-1.0°F @212°F 
  +/-1.8°C
  @500°C/ +/-3.6°F @932°F 
   | 
 
 
  | 
   Stability 
   | 
  
   +/-0.1°C
  @100°C/ +/-0.2°F @212°F 
  +/-0.3°C
  @500°C/ +/-0.6°F @932°F 
   | 
 
 
  | 
   Target
  size 
   | 
  
   2.25
  (57 mm) 
   | 
 
 
  | 
   Target
  Emissivity 
   | 
  
   0.95 
   | 
 
 
  | 
   Resolution 
   | 
  
   0.1°C/°F 
   | 
 
 
  | 
   Heating
  Time 
   | 
  
   40
  minutes to max 
   | 
 
 
  | 
   Cooling
  Time 
   | 
  
   45
  minutes to max to 100°C 
   | 
 
 
  | 
   Power 
   | 
  
   230
  VAV (+/-10%), 1.5A; or 110V AC, 3A 
   | 
 
 
  | 
   Size
  (H * W * D) 
   | 
  
   180
  mm * 114 mm * 233 mm 
   | 
 
 
  | 
   Weight 
   | 
  
   2682
  g 
   |