771/772/773 Milliamp Clamp Meter
|
The
Fluke mA Clamp Meters will save you time and money. These charts show you how
based on features/ benefits and then in
|
dollars and cents.
|
|
Product category/
Major features
|
General benefits
|
Specific benefits
|
Value
|
771
|
772
|
773
|
Measure mA signals for PLC and
control system/analog I/O without breaking the loop
|
Measures low level dc current
|
Correlate process indication with
real physical value
|
Saves process downtime and money
for automation professionals
|
●
|
●
|
●
|
Measure output signals from
transmitters without breaking the loop
|
Maintain and troubleshoot process
and automation equipment without breaking the loop
|
No disruption to the process
|
Saves process downtime and money
for instrumentation professionals
|
●
|
●
|
●
|
Detachable clamp with extension
cable
|
Measurements in tight locations
|
Enables measurements in difficult
situations
|
Measurements can be quickly
carried out
|
●
|
●
|
●
|
Source, simulate and measure mA
signals in circuit (break the loop)
|
Confirm non-contact measurement.
Have the next tool in hand
for troubleshooting (source
simulate)
|
Eliminates need to return to shop
to get a loop calibrator for troubleshooting after finding a bad signal with
non-contact measurement
|
Helps speed up loop
troubleshooting
saves time and money
|
|
●
|
●
|
Source and measure V dc
|
Troubleshoot voltage input and
output devices
|
Measure presence of 24 V loop
power. Measure 1 to 5 or 0 to 10 V process signals.
|
Eliminates need to return to shop
to get a voltage source tool or a DMM. Saves time and money.
|
|
|
●
|
4 to 20 mA in/out
|
Dual channel mA source and
measurement for troubleshooting
|
Source 4 to 20 mA signals into
valves and signal conditioners and simultaneously measure 4 to 20 mA
positioning output signals.
|
Quick troubleshooting of devices
with mA inputs and outputs. Save time and money.
|
|
|
●
|
4 to 20 mA scaled output
|
Scaled mA output provides a mA
signal output representative of the measured mA value
|
Connect a logging DMM and log the
mA signal without breaking the loop
|
Troubleshoot and document
intermittent or erratic 4 to 20 mA loop signals
|
|
|
●
|
Loop power supply
|
Power a transmitter
|
Substitute testing of the
installed 24 V loop power supply. Power a transmitter and measure its mA
output signal for troubleshooting.
|
Eliminates need to return to shop
to get a power supply. Saves time and money.
|
|
●
|
●
|
Dual backlit display with both mA
measurement and percent of 4 to 20 mA span
|
Clear measurement presentation
|
Quick measurement evaluation
|
Saves time, saves money
|
●
|
●
|
●
|
Measurement Spotlight
|
Illuminates hard to see wires in
dark enclosures
|
Measurement process is easier and
quicker
|
Saves time
|
●
|
●
|
●
|
Measure up to 99.9 mA range
non-contact
|
Wide range of measurements
|
Measures 10 to 50 mA signals in
older control systems
|
Only one instrument needed for
multiple applications
|
●
|
●
|
●
|
Automatic power off
|
After 15 minutes and 2 minute
automatic off for backlight and spotlight
|
Saves battery life
|
Saves money on batteries
|
●
|
●
|
●
|