Deadweight Tester
|
|
Type 1305D, Accuracy (0.1%)
|
|
|
|
Ashcroft®
Type 1305D deadweight testers provide an easy means of precisely
generating
|
|
pressure to an accuracy of 0.1% of reading.
Ashcroft 1305D units are available for operating
|
|
ranges up to 10,000 psi.
They are ideal for use in calibrating, setting, testing and repairing
|
|
pressure measurement and control devices. Each
1305D unit is traceable to the National
|
|
Institute of Standards and Technology,
assuring instrument accuracy.
|
|
|
|
These pressure systems are designed to be field portable. A
single carrying case holds the
|
|
pressure
generation pump as well as all the necessary tools and accessories. A second
box
|
|
contains the weights
used for pressure generation (10,000 psi units
require two boxes of weights).
|
|
Ashcroft deadweight testers quality
as primary standards for pressure calibration.
|
|
|
|
The
pump is a two-stage hydraulic pressure generator. A built-in shuttle valve
allows for rapid
|
|
pressure increase at low pressures. The rate of
increase per pump cycle can be reduced at higher
|
|
pressures to minimize resistance. This is
accomplished by simply repositioning the two-position shuttle
|
|
valve. With the shuttle valve in the high-pressure
position, increasing pressure even when near the
|
|
10,000
psi upper limit can be accomplished quickly and
easily. Final, precise adjustment is
|
|
accomplished through the use of an
integral vernier-adjustment knob.
|
|
|
|
The 1305D is provided with two-piston cylinder assemblies. A
low-pressure piston for pressure ranges
|
|
from 15 to
2000 psi and a high-pressure unit for pressures
from 75 to 10,000 psi. The high-pressure
|
|
piston has an area of 1/80th of a square inch while
the low pressure piston has an area of 1/16th of
|
|
a square
inch. Weights are provided for pressure increments of 5, 10, 20, 25, 40, 50,
100, 200 and 500
|
|
psi
(depending on piston in use). An optional 1 psi
incremental weight is also available. Ashcroft 1305D
|
|
testers can be
used anywhere within their operational range without any change in accuracy.
The
|
|
same weights are
used with both piston and cylinder assemblies.
|
|
|
|
Ashcroft
1305 units are available for psi, bar, kg/cm2,
and kPa ranges. Each unit comes complete
|
|
with
a hand jack set (for removal of pointers on gauges being calibrated), spare
O-rings and all
|
|
tools, accessories and fitting required for normal
use.
|
|
|
|
1305D STANDARD PRESSURE
RANGES
|
|
psi Type
|
Piston Assembly
Pressure Range
|
Piston Value
|
Number of Weights by
Value
|
Net Weight
|
Low
|
High
|
Low
|
High
|
L-5
H-25
|
L-10
H-50
|
L-20
H-100
|
L-40
H-200
|
L-100
H-500
|
lb
|
kg
|
1305D-10
|
15/200
|
75/1000
|
5
|
25
|
1
|
3
|
2
|
3
|
-
|
60
|
27
|
1305D-20
|
15/400
|
75/2000
|
5
|
25
|
1
|
3
|
2
|
3
|
2
|
70
|
32
|
1305D-30
|
15/600
|
75/3000
|
5
|
25
|
1
|
3
|
2
|
3
|
4
|
85
|
39
|
1305D-50
|
15/1000
|
75/5000
|
5
|
25
|
1
|
3
|
2
|
3
|
8
|
105
|
48
|
1305D-100
|
15/2000
|
75/10,000
|
5
|
25
|
1
|
3
|
2
|
3
|
18
|
175
|
80
|
|
|
|
|
|
|
|
|
|
|
|
|
|