3 ½ DMM - 30 RANGES / 20A / TEMPERATURE / CAPACITANCE /
FREQUENCY
Features
- very
complete model
- low-battery
indication, overload protection and automatic deactivation
- transistor,
diode and audible continuity test
- DC
current max. 20A, DC voltage max. 1000V
- AC
current max. 20A, AC voltage max. 700V
- resistance
measurements: up to 20Mohm
- capacitance
measurements: from 2000pF to 20µF
- frequency
measurements: max. range 20kHz
- temperature
test range: from 0°C to 40°C through built-in sensor
- K-type thermocouple measuring range: from -20°C to 1000°C
(SONDE890, incl. or SONDE8264, not incl.)
- with
holster
- packaging:
blister
- Important safety information
Specifications
- DC
voltage: 200m/2/20/200/1000V
- basic
accuracy: ±0.5%
- input
impedance: 10Mohm
- maximum
input: 1000V
- AC
voltage: 2/20/200/700V
- basic
accuracy: ±0.8%
- input
impedance: 10Mohm
- frequency
range: 40-400Hz
- maximum
input: 750V
- DC
current: 2m/20m/200m/20A
- basic
accuracy: ±0.8% (±2.0% for 20A range)
- overload
protection: 0.2A (20A for 20A range)
- AC
current: 20m/200m/20A
- basic
accuracy: ±0.8% (±3.0% for 20A range)
- overload
protection: 0.2A (20A range not fused)
- resistance:
200/2k/20k/200k/2M/20M/200M
- basic
accuracy: ±0.8% (±5.0% for 200M range)
- overload
protection: 250V
- capacitance
: 2000p/20n/200n/2µ/20µF
- inductance:
-
- frequency:
20kHz
- basic
accuracy: ±1.0%
- overload
protection: 250V DC/AC
- temperature:
-50°C to 1000°C
- overrange:
yes "1"
- continuity
buzzer: yes
- transistor
test: yes
- diode
test: yes
- low-battery
indication: yes
- maximum
display: 1999
- LCD
display size: 31 x 61mm
- ranging
mode : manual
- data
hold: no
- backlight:
no
- dimensions:
88 x 170 x 38mm
- weight
(with battery): ± 340g
- power
supply: 9V battery (incl.)
- packing:
blister
- accessories:
manual / test leads / holster / battery / temp. probe
- auto
power-off: yes
|