DBC 150/650 Series
|
|
Dry block temperature calibrators
|
|
Ranges from
-45 to 650๐C
|
|
Rapid
heating, cooling and settling
|
|
Reads set
temperature and device output simultaneously
|
|
Measures
reference probe, RTD’s, T/C’s, mA,
mV and ohms
|
|
Switch test, ramp,
step and preset functions
|
|
Automated
calibration via RS 232
|
|
|
|
DBC Series – Key features
|
|
Ranges:
|
DBC150:
-45 (below ambient) to 150 ๐C.
DBC650: 50 to 650 ๐C.
|
|
Fast response:
|
Rapid
heating, cooling and settling.
|
|
Stability:
|
Druck control technology provides excellent temperature
stability.
|
|
Reference probe:
|
PT
100 reference probe input.
|
|
RS 232 interface:
|
Allows
fully automated PC control.
|
|
Switch test:
|
Open/closed
detection with hysteresis displayed.
|
|
Ramp, preset, step:
|
Programmable
Ramp, Preset recall and calibration Step sequences.
|
|
Reduction Inserts:
|
A
wide range of standard interchangeable inserts are available.
Inserts
can also be supplied to specific requirements.
|
|
Easy to use:
|
Full
numeric keypad and input/output menu.
|
|
|
|
TC version – additional features
|
|
The
calibrator version includes the following features in addition to those
listed above:
|
|
Electrical Inputs:
|
Measures
RTD’s, T/C’s, mV/V, mA
and ohms.
|
|
Dual Readout:
|
Simultaneous
reading of source temperature and device output.
|
|
Error Analysis:
|
Percentage
error and deviation calculations.
|
|
Loop Power:
|
24
Vd.c supply.
|
|
|
|
The
DBC series are rugged, easy to use and designed to give years of reliable
service. Stand alone
|
|
operation
eliminates the need for secondary equipment, making the DBC one of the most
cost-
|
|
effective temperature calibration systems available.
|
|
|
|
Applications
|
|
MULTIFUNCTION DRYBLOCK
CALIBRATORS
|
|
The
DBC series comprises of two models, the DBC TS Temperature Source and the stand
alone DBC TC
|
|
Temperature
Calibrator. They are designed for calibrating and maintaining temperature
elements,
|
|
probes, transmitters and thermostats. The two models
share the same temperature control technology
|
|
and differ only in electrical measurement capabilities.
|
|
|
|
DBC TS Temperature Source
|
|
The
DBC TS temperature source uses an internal high accuracy sensor to measure
the equalization block
|
|
temperature. Alternatively, for direct
measurement of the insert temperature, a PT 100 electrical input
|
|
is provided. Traceable reference probes are available. A
switch detection input is supported with a fully
|
|
automatic switch test facility.
|
|
|
|
DBC TC Temperature Calibrator
|
|
The
DBC TC temperature calibrator adds electrical measurement capabilities for RTD’s, thermocouples,
|
|
mA, mV/V and ohms. 24V
loop power is also provided. The dual parameter display is quickly configured
|
|
from the input/output menu to read the reference temperature,
the device output and the error. This is
|
|
a self-contained temperature calibration system for
stand-alone operation.
|
|
|
|
Calibrating RTD Sensors and
Thermocouple Sensors
|
|
With
conventional dryblock calibrators, ancillary indicators
are usually required to measure sensor outputs.
|
|
The
DBC TC temperature calibrator and measure 5 types of RTD and 11 types of thermocouple.
It
|
|
supports
2, 3, and 4 wire RTD configurations and provides automatic cold junction
compensation for
|
|
thermocouples.
|
|
|
|
Preset temperatures can be